use the web config tool to disable and then enable cf on your site, this
will re-create the connector as well.
On Fri, Jun 15, 2012 at 6:24 PM, John M Bliss <
bliss.john@gmai...> wrote:
>
> Just did when you suggested it. :-) Error persists.
>
> On Fri, Jun 15, 2012 at 12:18 PM, Russ Michaels <
russ@mich...>
> wrote:
>
> >
> > I presume you tried restarting IIS ?
> >
> >
> > On Fri, Jun 15, 2012 at 6:15 PM, John M Bliss <
bliss.john@gmai...>
> > wrote:
> >
> > >
> > > Hi. For the first time that I know of, my ACF8 / IIS server is
> returning
> > > the following for some requests:
> > >
> > > Service Unavailable.
> > >
> > > Technical description:
> > > 504 Gateway Time-out - The web server is not responding
> > >
> > > This is a new one for me. Suggestions on where to start?
> > >
> > > --
> > > John Bliss -
http://about.me/jbliss
> > >
> > >
> > >
> >
> >
>
>
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~|
Order the Adobe Coldfusion Anthology now!